A method of recovering the tin tetrachloride from the hot end coating of glass bottles is described. The method prevents the overpay from going out the stack as a visible plume, polluting the atmosphere, and corroding the plant and surrounding facilities. A venturi scrubber, with a pressure drop of 55in. of water or more across the venturi and an alkaline spray into the venturi throat, will successfully capture the micron and submicron size particles. As the fumes and liquid accelerate into the throat of the venturi, the scrubbing liquid is rapidly broken into micron size droplets.
Origin
Unknown
Journal Title
Glass Ind., 55(2): 6-7, 14, Feb 1974
Sector
Primary Papers
Class
PP 653