In a viscous liquid, matching of the Reynolds number should be sufficient to model flow patterns accurately, so room temperature modelling using this criterion should allow much useful preliminary work to be done on stirrer design and operating conditions. Quantitative assessment of homogeneity was made in the present work using a technique developed by Jambor-Sadeghi, but similar to that used by Cooper et al.
Origin
Inst Optics And Electronics, Chengdu, Prc
Journal Title
Jncs 80 1986 642-648
Sector
Special Glass
Class
S 3714