Experimental measurement of the dynamic internal temperature distribution in soda-lime glass plates using thermocouples fused in the glass has been carried out. Measured temperatures are compared with predictions obtained from solving the transient energy equation.
Origin
Purdue University
Journal Title
J Am Ceram Soc 1990 73 7 2047-2053
Sector
Flat glass
Class
F 235