A new laboratory testing for the analysis of glass/mould contact is proposed. The various components of the new installation and their kinematics, the choice of the measuring instruments and their accurate location are described. From the temperature evolution in the contact area, coupling inverse method and thermal computations by finite difference method leads to the transient estimation of the heat exchange coefficient at the glass/mould interface.
Origin
University Of Valenciennes
Journal Title
Verre 9 2 April 2003 24-27
Sector
Container glass
Class
C 2070