Surface tension parameters for oxide components in silicate glass melts were estimated using a multiple linear regression analysis on the values reported both in the literature and our own measured data. The values reported in the literature have a 1-5% internal error, the surface tension measured for this paper has an error of 1-3%. The F-test analysis showed that the regression is significant.
Origin
Alfred University, Usa
Journal Title
Glass Tech 40 5 1999 149-153
Sector
Special Glass
Class
S 1760