Fogging on the outside surfaces of window glazings increases if the thermal insulation of the glazing is improved, i.e. the k value is decreased as realized in heat-insulating glasses currently on the market. Common types open to risk are sky lights and glazing in the skin of buildings, e.g. structural glazing facades, because they are exposed to the largest portion of open sky. Conditions of fogging are investigated and discussed.
Origin
Inst Fur Nichtmetallische Werkstoffe, Germany
Journal Title
Glastech Ber Glass Sci Technol 70 5 1997 146-154
Sector
Flat glass
Class
F 731